Methods for estimating the ADC jitter in noncoherent systems
DOI:
https://doi.org/10.3103/S0735272711100037Keywords:
ADC, jitter, clock pulse generator, multichannel system, noncoherent system, harmonic signal, sampling, sampling frequencyAbstract
The paper presents the method of estimating the jitter dispersion developed for the case when the clock pulse generator of ADC and the generator of input test signal are not time synchronized. The generalization of the method was carried out for the following cases: input signal represents a sum of harmonic components; ADC system has several channels with equal values of the jitter and additive noise dispersions. The results of numerical simulation are also presented.
References
M. V. Bondarenko, “Phase Method of Estimation of Aperture Uncertainty Time,” Izv. Vyssh. Uchebn. Zaved., Radioelektron. 53(1), 48 (2010) [Radioelectron. Commun. Syst. 53(1), 42 (2010)].
F. Verbeyst, Y. Rolain, R. Pintelon, and J. Schoukens, “Enhanced Time Base Jitter Compensation of Sine Waves,” in Proc. of Instrumentation and Measurement Technology Conference (IMTC 2007), May 1–3, 2007, Warsaw, Poland (Warsaw, 2007), pp. 1–5.
I. S. Gradshtein and I. M. Ryzhik, Tables of Integrals, Sums, Series, and Products (Fizmatgiz, Moscow, 1963) [in Russian].
V. I. Slyusar, RF Patent No. 2054684, Byull. Izobret., No. 5 (1996).
V. I. Slyusar and V. G. Smolyar, “The Method of Nonorthogonal Frequency-Discrete Modulation of Signals for Narrow-Band Communication Channels,” Izv. Vyssh. Uchebn. Zaved., Radioelektron. 47(4), 53 (2004); Radioelectron. Commun. Syst. 47(4), 47 (2004).
V. A. Varyukhin, Fundamental Theory of Multichannel Analysis (VA PVO SV, Kyiv, 1993) [in Russian].