DOI: https://doi.org/10.3103/S0735272703020079
Open Access Open Access  Restricted Access Subscription Access

A six-port analyzer of microwave networks based on Fourier discrete transform of the tapped signals, and methods of its calibration

Yu. B. Gimpilevich, R. S. Bandyshev

Abstract


The authors have analyzed a new method suggested for measurement of complex-valued parameters of microwave circuits. The method is based on processing of the signals, applied to the measurement arms of a six-port, with the aid of Fourier discrete transform. A procedure for calibration of this analyzer with the aid of a set of impedance standards is developed. The results of the modeling the calibration procedure are presented.

Full Text:

PDF

References


ENGEN, G.F. "An improved circuit for implementing the six-port technique of microwave measurements," IEEE Trans. Microwave Theory Tech., v.25, n.12, p.1080-1083, 1977. DOI: https://doi.org/10.1109/TMTT.1977.1129278.

GIMPELEVITCH, Yu.B. "A technique for identification of microwave circuitry complex-valued parameters," RF Patent No. 2022284, Int. Cl. G01R 27/06, Published 30 October 1994 in Bull. Izobr., n.20, 1994.

BASKAKOV, S.I. Radio-Engineering Circuits and Signals [in Russian]. Moscow: Vysshaya Shkola, 1988.







© Radioelectronics and Communications Systems, 2004–2019
When you copy an active link to the material is required
ISSN 1934-8061 (Online), ISSN 0735-2727 (Print)
tel./fax +38044 204-82-31, 204-90-41